Posts Topics Forums Images
Search videos from message boards Videos Search messages from microblogs Microblogs Search messages from imdb.com Imdb Search messages from yuku.com Yuku Search messages from lefora.com (free forums) Lefora
My account: Login | Sign Up
Loading... 

Power Factor | Topic profile

Topic profile page for Power Factor. This page has aggregated data from forum posts, threads, listings, online discussions, newsgroups, messageboards, and other online sources which contain user generated content for the term: Power Factor.
Topic "Power factor" was discussed 0 times on 0 sites in last 3 months
Search discussions, forums, images, videos, about "Power factor" on BoardReader!
 

BoardReader Trendy!

Topic 1:

Topic 2:

Topic 3:

Domain Profile
Domain:

Posting activity graph on power factor:

Posts by:  day  week  month 

 

Related topics:


power factor was discussed on the following sites:

Glock Talk - 179 Glock Talk - site profile
Eng-Tips Forums Eng-Tips Forums - 143 Eng-Tips Forums - site profile
DIY & home improvement forum - DIYbanter DIY & home improvement forum - DIYbanter - 135 DIY & home improvement forum - DIYbanter - site profile
1911Forum 1911Forum - 99 1911Forum  - site profile
THR THR - 69 THR - site profile

 

Related threads on power factor:

Competition Shooting Power factor chart  THR - site profile Competition Shooting - forum profile  Go to this thread  Power factor chart
Power Electronics power factor improvement and reduction of total harmonic...  Electronics Lab - Community - site profile Power Electronics - forum profile  Go to this thread  power factor improvement and reduction of total harmonic distortion of rectifier
coloncleanse911 Published a new post: Why Power Factor Correction and...  coloncleanse911 - Identi.ca - site profile coloncleanse911 - forum profile  Go to this thread  Published a new post: Why Power Factor Correction and TVSS Do Not Save Energy http://tinyurl.com/yd3dyns
MarkFromHawaii Word to the wise: If you are approached by someone...  Twitter / MarkFromHawaii - site profile MarkFromHawaii - forum profile  Go to this thread  Word to the wise: If you are approached by someone selling a "power factor correction/energy saving" device - it's BOGUS. 11:48 PM Nov 3rd from web
Electric motors & motor controls engineering VFD input power factor  Eng-Tips Forums - site profile Electric motors & motor controls engineering - forum profile  Go to this thread  VFD input power factor

Latest threads on power factor:

Electric motors & motor controls engineering
Started 22 hours, 48 minutes ago (2009-12-19 13:02:00)  by daldesign
We design exercise equipment, some using DC drives and some using AC drives. They are in-house designs. The AC drive is a simple V/F type and exhibits poor PF (0.7 or less) owing to its front-end being a simple bridge rectifier and capacitor design. The supply is 240V 60Hz single-phase. The output is 3-phase 230VAC 10 to 120Hz. The motor is 2hp. To improve the PF we can add a series inductance ...
Source: Eng-Tips Forums More from this site Eng-Tips Forums - site profile 
Forum:  Electric motors & motor controls engineering  Electric motors & motor controls engineering - forum profile
Thread:  Show this thread (2 posts) More from vfd power factor  Thread Thread info: vfd power factor Size: 690 bytes
Related Threads: Same Site | All Sites
Customize:  Customize "vfd power factor :: Electric motors & motor controls engineering :: Eng-Tips Forums"
melekh
Started 1 day, 13 hours ago (2009-12-18 22:47:33)  by melekh
Source: melekh - Identi.ca More from this site melekh - Identi.ca - site profile 
Forum:  melekh  melekh - forum profile
Thread:  Show this thread (1 post) More from eltrovi.com post: Why Power Factor Correction and TVSS Do Not Save Energy http://tinyurl.com/yk7hkhw  Thread Thread info: eltrovi.com post: Why Power Factor Correction and TVSS Do Not Save Energy http://tinyurl.com/yk7hkhw Size: 329 bytes
Related Threads: Same Site | All Sites
Customize:  Customize "eltrovi.com  post: Why Power Factor Correction and TVSS Do Not Save Energy  http://tinyurl.com/yk7hkhw :: melekh :: melekh - Identi.ca"
coloncleanse911
Started 1 day, 13 hours ago (2009-12-18 22:46:16)  by coloncleanse911
Source: coloncleanse911 - Identi.ca More from this site coloncleanse911 - Identi.ca - site profile 
Forum:  coloncleanse911  coloncleanse911 - forum profile
Thread:  Show this thread (1 post) More from Published a new post: Why Power Factor Correction and TVSS Do Not Save Energy http://tinyurl.com/yduj99y  Thread Thread info: Published a new post: Why Power Factor Correction and TVSS Do Not Save Energy http://tinyurl.com/yduj99y Size: 267 bytes
Related Threads: Same Site | All Sites
Customize:  Customize "Published a new post: Why Power Factor Correction and TVSS Do Not Save Energy  http://tinyurl.com/yduj99y :: coloncleanse911 :: coloncleanse911 - Identi.ca"
coloncleanse911
Started 1 day, 13 hours ago (2009-12-18 22:45:37)  by coloncleanse911
Source: coloncleanse911 - Identi.ca More from this site coloncleanse911 - Identi.ca - site profile 
Forum:  coloncleanse911  coloncleanse911 - forum profile
Thread:  Show this thread (1 post) More from Published a new post: Why Power Factor Correction and TVSS Do Not Save Energy http://tinyurl.com/yd3dyns  Thread Thread info: Published a new post: Why Power Factor Correction and TVSS Do Not Save Energy http://tinyurl.com/yd3dyns Size: 260 bytes
Related Threads: Same Site | All Sites
Customize:  Customize "Published a new post: Why Power Factor Correction and TVSS Do Not Save Energy  http://tinyurl.com/yd3dyns :: coloncleanse911 :: coloncleanse911 - Identi.ca"
coloncleanse911
Started 1 day, 13 hours ago (2009-12-18 21:59:11)  by coloncleanse911
Source: coloncleanse911 - Identi.ca More from this site coloncleanse911 - Identi.ca - site profile 
Forum:  coloncleanse911  coloncleanse911 - forum profile
Thread:  Show this thread (1 post) More from Published a new post: Buyer Beware - Using Power Factor Correction and Transient Voltage Surge Suppression to Reduce Energy Costs http://tin  Thread Thread info: Published a new post: Buyer Beware - Using Power Factor Correction and Transient Voltage Surge Suppression to Reduce Energy Costs http://tin Size: 203 bytes
Related Threads: Same Site | All Sites
Customize:  Customize "Published a new post: Buyer Beware - Using Power Factor Correction and Transient Voltage Surge Suppression to Reduce Energy Costs... :: coloncleanse911 :: coloncleanse911 - Identi.ca"
Electric motors & motor controls engineering
Started 3 days, 18 hours ago (2009-12-16 17:10:00)  by GamecockEngr
We have checked the voltage meters used to sync and they are good as are the PT's used to read the voltage. We just installed a new excitation system. The generator terminal voltage is controlling to the proper set point and the dc is balanced perfectly. Here is the problem...when we tie on the MVARS are running ~60-80 MVARS at almost no load (5-10 MW). Usually we run 0-10 MVARS at 0-10 MW. The...
Source: Eng-Tips Forums More from this site Eng-Tips Forums - site profile 
Forum:  Electric motors & motor controls engineering  Electric motors & motor controls engineering - forum profile
Thread:  Show this thread (11 posts) More from 400MW Generator pulling too many MVARS (lagging power factor)  Thread Thread info: 400MW Generator pulling too many MVARS (lagging power factor) Size: 625 bytes
Related Threads: Same Site | All Sites
Customize:  Customize "400MW Generator pulling too many MVARS (lagging power factor) :: Electric motors & motor controls engineering :: Eng-Tips Forums"
Handloading and Reloading
Started 5 days, 20 hours ago (2009-12-14 14:55:00)  by DesmoDucRob
W231 Is my go-to powder for a few reasons. I like it; I shoot primarily 9mm in USPSA production division, and use 124 grain cast round nose from Missouri Bullet Co. There is little smoke, and no leading to speak of with either my LWD barrel or my factory polygonally rifled barrel. I notice that many folks who use W231 and 125 grain cast bullets claim that you will make power factor at 4.1 ...
Source: THR More from this site THR - site profile 
Forum:  Handloading and Reloading  Handloading and Reloading - forum profile
Thread:  Show this thread (8 posts) More from Knowing When I've made the Velocity (power factor) goal?  Thread Thread info: Knowing When I've made the Velocity (power factor) goal? Size: 1,128 bytes
Related Threads: Same Site | All Sites
Customize:  Customize "Knowing When I've made the Velocity (power factor) goal? :: Handloading and Reloading :: THR"
UK diy
Started 1 week, 1 day ago (2009-12-11 21:41:00)  by Andrew Gabriel
In article , John Rumm writes: Since my answer to a question on PF a while ago seemed well received, I thought I may as well hack it about a bit for a wiki article. Comments, edits etc as you see fit: http://wiki.diyfaq.org.uk/index.php?title=Power_fa ctor John, it's discussing power factor only in the context of phase shift (which was the context of the original ...
Source: DIY & home improvement forum - DIYbanter More from this site DIY & home improvement forum - DIYbanter - site profile 
Forum:  UK diy  UK diy - forum profile
Thread:  Show this thread (12 posts) More from Power factor  Thread Thread info: Power factor Size: 1,064 bytes
Related Threads: Same Site | All Sites
Customize:  Customize "Power factor :: UK diy :: DIY & home improvement forum - DIYbanter"
Introductory Physics
Started 1 week, 2 days ago (2009-12-10 15:07:00)  by libelec
1. The problem statement, all variables and given/known data The power factor of a circuit has to be improved from 0,6 to 0,9 by adding capacitors. Originally, it only has an inductor L, a resistence R and a generator V. The circuit requires an active power of 3000 VA, and that should remain the same. V ef = 220V. 3. The attempt at a solution ...
Source: Physics Help and Math Help - Physics Forums More from this site Physics Help and Math Help - Physics Forums - site profile 
Forum:  Introductory Physics  Introductory Physics - forum profile
Thread:  Show this thread (1 post) More from Improving power factor using capacitors (what capacitance?)  Thread Thread info: Improving power factor using capacitors (what capacitance?) Size: 1,636 bytes
Related Threads: Same Site | All Sites
Customize:  Customize "Improving power factor using capacitors (what capacitance?) :: Introductory Physics :: Physics Help and Math Help - Physics Forums"
Started 1 week, 3 days ago (2009-12-09 22:39:00)  by Charlie007
Read the article here: Electric motor efficiency depends upon power factor - Part 2
 

Hot threads on power factor:

top10world
Started 1 week, 1 day ago (2009-12-11 22:32:00)  by top10world
Source: top10world - Identi.ca More from this site top10world - Identi.ca - site profile 
Forum:  top10world  top10world - forum profile
Thread:  Show this thread (1 post) More from [Blog] How to Facto...: I... http://www.howto.com.my/2009/answer-this-if-you-can/how-to-factor-polynomials-with-x-to-the-3rd-or-4th-power/  Thread Thread info: [Blog] How to Facto...: I... http://www.howto.com.my/2009/answer-this-if-you-can/how-to-factor-polynomials-with-x-to-the-3rd-or-4th-power/ Size: 397 bytes
Related Threads: Same Site | All Sites
Customize:  Customize "[Blog] How to Facto...: I...  http://www.howto.com.my/2009/answer-this-if-you-can/how-to-factor-polynomials-with-x-to-the-3rd-or-4th-power/ :: top10world :: top10world - Identi.ca"
top10world
Started 1 week, 1 day ago (2009-12-11 22:32:18)  by top10world
Source: top10world - Identi.ca More from this site top10world - Identi.ca - site profile 
Forum:  top10world  top10world - forum profile
Thread:  Show this thread (1 post) More from [Blog] How to Factor Polynomials with x to the 3rd or 4th power?: I understand how to... http://www.howto.com.my/2009/answer-this-if-you-can  Thread Thread info: [Blog] How to Factor Polynomials with x to the 3rd or 4th power?: I understand how to... http://www.howto.com.my/2009/answer-this-if-you-can Size: 284 bytes
Related Threads: Same Site | All Sites
Customize:  Customize "[Blog] How to Factor Polynomials with x to the 3rd or 4th power?: I understand how to...  http://www.howto.com.my/2009/answer-this-if-you-can :: top10world :: top10world - Identi.ca"
shuntezwood
Started 3 days, 23 hours ago (2009-12-16 12:05:44)  by shuntezwood
Source: shuntezwood - Identi.ca More from this site shuntezwood - Identi.ca - site profile 
Forum:  shuntezwood  shuntezwood - forum profile
Thread:  Show this thread (1 post) More from Power Of Social Media - Facebook Campaign Fights Against X-Factor: ... fans started claiming it was sabotage. T.. http://bit.ly/7Jz7hs  Thread Thread info: Power Of Social Media - Facebook Campaign Fights Against X-Factor: ... fans started claiming it was sabotage. T.. http://bit.ly/7Jz7hs Size: 375 bytes
Related Threads: Same Site | All Sites
Customize:  Customize "Power Of Social Media - Facebook Campaign Fights Against X-Factor: ... fans started claiming it was sabotage. T..  http://bit.ly/7Jz7hs :: shuntezwood :: shuntezwood - Identi.ca"
girishmallya
Started 5 days, 19 hours ago (2009-12-14 16:17:00)  by girishmallya
Source: Twitter / girishmallya More from this site Twitter / girishmallya - site profile 
Forum:  girishmallya  girishmallya - forum profile
Thread:  Show this thread (1 post) More from @sidtap you need to understand/factor in that a good chuck of tweets from
power users are replies or interactions/conversations  Thread Thread info: @sidtap you need to understand/factor in that a good chuck of tweets from
power users are replies or interactions/conversations Size: 662 bytes
Related Threads: Same Site | All Sites
Customize:  Customize "@ sidtap  you need to understand/factor in that a good chuck of tweets from power users are replies or interactions/c... :: girishmallya :: Twitter / girishmallya"
UK diy
RE: Power factor  - 12 new posts Read thread in new window
Started 3 days, 1 hour ago (2009-12-17 10:30:00)  by Mark[_30_]
On Thu, 17 Dec 2009 01:27:58 +0000 (UTC),
Source: DIY & home improvement forum - DIYbanter More from this site DIY & home improvement forum - DIYbanter - site profile 
Forum:  UK diy  UK diy - forum profile
Thread:  Show this thread (12 posts) More from Power factor  Thread Thread info: Power factor Size: 3,656 bytes
Related Threads: Same Site | All Sites
Customize:  Customize "RE: Power factor :: UK diy :: DIY & home improvement forum - DIYbanter"
Electric motors & motor controls engineering
Started 2 days, 4 hours ago (2009-12-18 07:46:00)  by nawao
Invert the polarity of the droop CT and see how is the behaviour
Source: Eng-Tips Forums More from this site Eng-Tips Forums - site profile 
Forum:  Electric motors & motor controls engineering  Electric motors & motor controls engineering - forum profile
Thread:  Show this thread (11 posts) More from 400MW Generator pulling too many MVARS (lagging power factor)  Thread Thread info: 400MW Generator pulling too many MVARS (lagging power factor) Size: 114 bytes
Related Threads: Same Site | All Sites
Customize:  Customize "RE: 400MW Generator pulling too many MVARS (lagging power factor) :: Electric motors & motor controls engineering :: Eng-Tips Forums"
منتدى الهندسة الكهربائية
Started 1 week ago (2009-12-12 19:39:00)  by حيدر علاج حسن
ممتاز اخي احمد . الآن اصبحت الفكرة جدا واضحة . شكرا جزيلا . __________________ اسئلكم الدعاء لاخينا صفوان . اللهم ابدل عسره يسرا , مقالات المهندس حيدر علاج حسن
Handloading and Reloading
Started 1 day, 20 hours ago (2009-12-18 15:35:00)  by DesmoDucRob
Quote: You being one of those sciency guys, I'm sure you can figure when Excel function that is!! Yeah, but I try to keep work at work. Seriously, though you're right on the money. The only reason I haven't reduced my load is for fear of a round randomly falling below power factor. Once I can reach that 10% SD mark you mentioned, I'll pretty ...
Source: THR More from this site THR - site profile 
Forum:  Handloading and Reloading  Handloading and Reloading - forum profile
Thread:  Show this thread (8 posts) More from Knowing When I've made the Velocity (power factor) goal?  Thread Thread info: Knowing When I've made the Velocity (power factor) goal? Size: 910 bytes
Related Threads: Same Site | All Sites
Customize:  Customize "RE: Knowing When I've made the Velocity (power factor) goal? :: Handloading and Reloading :: THR"
منتدى الهندسة الكهربائية
Started 1 week ago (2009-12-12 19:39:00)  by حيدر علاج حسن
ممتاز اخي احمد . الآن اصبحت الفكرة جدا واضحة . شكرا جزيلا .
أرشيف اللقاءات
Started 5 days, 15 hours ago (2009-12-14 20:41:00)  by احمد محمد مد
       مساحة إعلانية القدرة p1 ,p2 متساوية لانها تمثل قدرة المحركات والمتغير هو التيار المسحوب من الشبكة وبالتالى يقل التيار المسحوب وكذلك الفقد عند شركة الكهرباء والاستفادة العملية للمشترك هى رفع الغرامات الخاصة بمعامل القدرة لان القياس يكون قبل لوحات المكثفات وكذلك قبل الاحمال والتحسن يكون قبل الحمل وتركيب المكثفات مفيدة جدا بالنسبة للمشترك ...
Source: www.arab-eng.org More from this site www.arab-eng.org - site profile 
Forum:  أرشيف اللقاءات   أرشيف اللقاءات   - forum profile
Thread:  Show this thread (18 posts) More from سؤال بخصوص معامل القدرة power factor - الصفحة 3 -
ملتقى المهندسين العرب - أول ملتقى هندسي
عربي  Thread Thread info: سؤال بخصوص معامل القدرة power factor - الصفحة 3 -
ملتقى المهندسين العرب - أول ملتقى هندسي
عربي Size: 1,370 bytes
Related Threads: Same Site | All Sites
Customize:  Customize "RE: سؤال بخصوص معامل القدرة power factor - الصفحة 3 - ملتقى المهندسين العرب - أول ملتقى هندسي عربي :: أرشيف اللقاءات   :: www.arab-eng.org"
Other Shooting Sports Discussions
RE: GSSF Power Factor  - 2 new posts Read thread in new window
Started 6 days, 4 hours ago (2009-12-14 07:15:00)  by Flexmoney
QUOTE (beulahkilborn781 @ Dec 14 2009, 07:46 AM) Also, every GSSF match I have ever been to has been won by a Glock Well...that is just lucky !